EMDN Annual Revision v.2026: What Changed and What to Check Before You Register in EUDAMED

The European Commission has published the 2026 annual revision of the European Medical Device Nomenclature (EMDN) across three MDCG documents: MDCG 2026-1, MDCG 2026-2, and MDCG 2026-3. With EUDAMED mandatory registration coming into force on 28 May 2026, the timing is directly relevant. Every device record uploaded to EUDAMED must carry a valid EMDN code, and codes from earlier versions that have been amended or deprecated in the v.2026 revision will cause registration errors in the device module.

If you haven’t yet reviewed the changelog against your current EMDN codes, now is the time.

What MDCG 2026-1 covers

MDCG 2026-1 documents the outcomes of the 2025 public consultation on the EMDN and the MDCG Nomenclature Working Group review. It groups the submissions from manufacturers, industry associations, and other stakeholders into three categories.

Not accepted submissions were rejected on one of four grounds: insufficient technical detail to support the request; the device in question is not yet on the EU market; the request fell outside the defined scope of the annual update process (for example, requests to restructure major sections of the nomenclature); or the request would have had too large an impact on existing codes, such as proposals to align the EMDN wholesale to ISO 9999. Manufacturers whose submissions were not accepted will need to resubmit with additional technical evidence in the next consultation cycle, or identify the closest existing code in the meantime.

Accepted and partially accepted submissions have been incorporated into EMDN v.2026. MDCG 2026-1 documents the rationale for each decision. The full updated nomenclature is reflected in MDCG 2026-2 (the changelog) and MDCG 2026-3 (the version history).

Key changes in the v.2026 revision

The following accepted and partially accepted changes are of particular practical relevance for manufacturers preparing EUDAMED device registrations.

Neurovascular devices (section C): new codes added

A new section C010404 (Neurovascular Angiography Devices) has been added under C0104 (Angiography and Haemodynamic Devices). It covers C01040401 (Neurovascular Angiography Diagnostic Devices, including neurovascular occlusion catheters) and C01040402 (Neurovascular Angiography Therapeutic Devices, covering embolisation catheters, embolisation coils, mechanical assistance devices for embolisation, guide catheters, and thrombectomy and thromboaspiration systems).

A new section C0404 (Neurovascular Guidewires) has also been added alongside the existing coronary and peripheral vascular guidewire sections, covering diagnostic and therapeutic neurovascular guidewires in both hydrophilic and non-hydrophilic variants.

Manufacturers of neurovascular intervention devices who previously registered under general cardiovascular or vascular codes should review whether their devices now have more specific applicable codes under C010404 or C0404.

Hearing implants (section J): terminology updated, bone conduction added

The terminology for J0301, J0302, and J0303 has been updated (Cochlear Implants, Middle Ear Implants, and Auditory Brainstem Implants respectively). A new code J0304 (Bone Conduction Implants) has been introduced. Manufacturers of hearing implants should check whether existing EUDAMED device records use the previous terminology and update accordingly.

Robotic surgery instruments (sections K and L): new codes

K01010106 (Robotic Surgery Trocar, Single-Use) and L031206 (Robotic Surgery Trocar, Reusable) have been added. Within the reusable robotic surgery instruments section (L13), L1308 (Robotic Surgery Needle Holders, Reusable) has been added. Manufacturers who previously coded robotic surgery instruments under generic trocar or instrument categories should review these new codes.

Dental devices (section Q): root canal irrigation and revised terminology

Q01010302 (Solutions for Canal Irrigation) has been added under Q010103 (Dental Irrigation and Medication Devices). The existing code Q01010103 has been updated to Dental Restorative Composites, replacing the previous term Dental Conservation Composites. Manufacturers of dental irrigation solutions and composites should update device records to reflect the revised terminology and new codes.

Non-implantable devices for sexual dysfunction (section U): new addition

A new code U14 (Non-Implantable Devices for Sexual Dysfunction) has been added at the second level of the urogenital section. This fills a gap in the previous nomenclature for single-use devices in this category.

Temperature measurement (section V): finer granularity

V03010105 (Liquid Crystal Body Temperature Indicators) has been added alongside the existing digital and liquid expansion thermometer codes. V0301010201 (Contact Digital Thermometers, including probes) and V0301010202 (Non-Contact Digital Thermometers) provide additional granularity under V03010102.

Patient transfer equipment (section V): slides and transport sheets

V080505 (Patient Transfer Sheets and Mattresses) has been added under V0805 (Patient Transfer Equipment), covering single-use slide sheets and transport sheets. Manufacturers of patient transfer disposables should check whether this code applies to their products.

IVD reagents (section W): Presepsin added

W0102019018 (Presepsin, soluble CD14 or sCD14) has been added under the Specific Proteins subsection. The accompanying note confirms this code was not included in EMDN v.2025 and was introduced based on input outside the 2025 public consultation. IVD manufacturers offering presepsin (sCD14) assays should use this new code.

Vital signs monitoring (section Z): telemetry reorganised

Z12030206 (Vital Signs Telemetry Instruments) has been introduced as a subsection under Z120302 (Vital Signs Monitoring Instruments), consolidating telemetry instruments under the monitoring category. Manufacturers of vital signs telemetry systems, transmitters, and receivers should verify whether their existing EUDAMED codes reflect this reorganisation.

Blood transfusion instruments (section Z): thawer codes expanded

Z121703 has been updated from Plasma Thawers to Blood Products Thawers, with new subcodes Z12170301 (Plasma Thawers), Z12170302 (Cryopreserved Blood Products Thawers), and Z12170399 (Blood Products Thawers, Other). Manufacturers of blood component thawers should update their EMDN codes to the appropriate subcode.

What manufacturers need to do before registering in EUDAMED

The EUDAMED UDI/Devices module becomes mandatory on 28 May 2026. Before uploading device data, work through the following steps:

  1. Download the MDCG 2026-2 changelog (linked in the sources below). It lists every code change in the 2026 revision, including amendments, new additions, and deprecations.
  2. Cross-reference your current EMDN codes against the changelog to identify any that have been amended, merged, or deprecated. Where a code has changed, identify the correct current code for your device. In some cases, the 2026 revision introduces additional granularity, meaning the appropriate choice is now a more specific subcode rather than the parent code you previously used.
  3. Update your device registration data before upload. Attempting to register with a deprecated or renamed code will cause an error in the EUDAMED device module, and this will need to be resolved before the record can be submitted.

MDCG 2026-3 (the version history) provides the complete lineage of every code change since the EMDN was introduced. If you need to trace when a specific code was changed, understand the reason for a deprecation, or verify how a code maps across versions, MDCG 2026-3 is the definitive reference.

Need a hand with EUDAMED registration?

EUDAMED device registration is one of those tasks that looks straightforward on paper and has a habit of surfacing complications at the worst possible moment. Between EMDN code validation, UDI assignment, economic operator SRNs, and certificate linkage, there are a lot of moving parts.

If you’d like a second pair of eyes on your EUDAMED readiness before 28 May, we’re happy to help. Get in touch and we’ll work through it with you.

References