From 18 February 2027, certain batteries placed on the EU market will need a battery passport under Article 77 of the Batteries Regulation (Regulation (EU) 2023/1542). The European Commission is now preparing an implementing act on who may access which parts of the passport, and the initiative has appeared on the Commission’s Have Your Say portal. Medical device manufacturers have asked whether the passport affects them. For most devices it does not, but some larger equipment and mobility devices may fall within scope, and other battery obligations that start on the same date apply far more widely.
What the battery passport is
The battery passport is an electronic record for an individual battery, accessed through a QR code on the battery. It holds information on the battery’s composition, performance, durability, carbon footprint and end-of-life handling. Under Annex XIII of the Regulation, part of the passport is public, part is available only to notified bodies, market surveillance authorities and the Commission, and part is reserved for persons with a legitimate interest, such as repairers, remanufacturers and recyclers. The implementing act now in preparation will set out access for that last group.
The Regulation required the access rules to be adopted by 18 August 2026. That date was missed. The passport obligation itself still applies from 18 February 2027.
Which batteries need a passport
The passport applies to three categories:
- light means of transport (LMT) batteries, which are sealed batteries of 25 kg or less designed to power wheeled vehicles such as e-bikes and e-scooters
- industrial batteries with a capacity greater than 2 kWh
- electric vehicle batteries
It does not apply to portable batteries. A portable battery is one that is sealed, weighs 5 kg or less and is not designed specifically for industrial use. Most batteries in medical devices fall into this category, including those in handheld instruments, monitors, infusion pumps, hearing aids and wearable devices.
Where medical devices may be affected
Two groups of devices are worth checking.
Large equipment with high capacity batteries. An industrial battery is one designed for industrial use or any battery over 5 kg that is not an LMT, electric vehicle or starter battery. Mobile imaging systems, battery powered carts and other large electromechanical equipment may contain batteries above 5 kg and above 2 kWh. If so, the battery needs a passport.
Powered mobility devices. Powered wheelchairs and mobility scooters use traction batteries that power a wheeled vehicle. Depending on their weight and design, these batteries may meet the LMT definition. Manufacturers should confirm the classification of each battery with their battery supplier.
Responsibility sits with the economic operator that places the finished battery on the EU market. The Commission’s guidance confirms that the Regulation applies to batteries incorporated into other products. Where a device manufacturer buys a finished battery from a supplier, the supplier will usually be responsible for the passport. Where the device manufacturer assembles the battery pack or imports equipment with a battery already installed, the responsibility may fall on the device manufacturer or importer.
The obligations that matter more for most devices
For most device manufacturers, the February 2027 obligations that need attention are elsewhere in the Regulation.
Removability and replaceability (Article 11). From 18 February 2027, portable batteries in appliances must be removable and replaceable by the end user. The Regulation allows replacement by independent professionals instead for professional medical imaging and radiotherapy devices and for IVDs, and the requirement does not apply where continuity of power supply is needed for safety or data integrity. A delegated regulation adopted by the Commission on 14 July 2026, and subject to scrutiny by the European Parliament and the Council, adds further products to these partial exemptions, including on-body delivery systems for subcutaneous administration of medicinal products. Devices that fall outside these exemptions need to meet the requirement.
QR code labelling (Article 13). Batteries will need a QR code giving access to information about the battery, from 18 February 2027 at the earliest. The final date depends on supporting legislation.
Northern Ireland. The Batteries (Placing on the Market) (Northern Ireland) Regulations 2026 now put enforcement and penalties behind the EU Batteries Regulation in Northern Ireland, so devices supplied there are subject to the same dates.
What to do now
- List every battery in your product range, with its weight, capacity and chemistry.
- Classify each battery as portable, LMT or industrial, and identify any industrial battery above 2 kWh.
- For any battery in passport scope, confirm in writing who will provide the passport.
- For portable batteries, check each device against the Article 11 removability requirement and the exemptions, and record your conclusion in the technical documentation.
- Review labelling plans for the QR code requirement.
Specculo advises device and IVD manufacturers on EU and UK market access, including product legislation that applies alongside the MDR and IVDR. If you would like help assessing how the Batteries Regulation affects your devices, get in touch.