What Medical Device Manufacturers Need to Know About the 2024 PMS Amendments
The Medical Devices (Post-market Surveillance Requirements) (Amendment) (Great Britain) Regulations 2024 to the UK Medical Devices Regulations 2002 (UK MDR 2002) introduce a new, legally binding framework for how medical device manufacturers must monitor and manage product safety and performance once their devices are on the market in Great Britain. The changes introduced by Statutory Instrument (SI) 2024 No. 1368 apply to all devices placed on the GB market, whether UKCA-marked or CE-marked under transitional arrangements, and come into force on 16 June 2025.
At the core of the amendment is the requirement for manufacturers to adopt a proactive and systematic approach to PMS. This means going beyond passive complaint handling and vigilance reporting to actively collecting, analysing, and responding to post-market data. Every device must now be supported by a PMS Plan that outlines how real-world data will be gathered, what sources will be used, how risks will be evaluated, and what actions will be taken in response to new information.
The amendments aim to bring UK post-market requirements closer in line with international standards, improve traceability and transparency, and empower the MHRA to intervene more quickly when safety concerns arise. For manufacturers, this represents both a compliance obligation and an opportunity to strengthen product lifecycle management and patient safety.
Following the introduction of this new framework, the 2024 regulations amend UK MDR 2002 by inserting Part 4A, which formally sets out the new PMS requirements across all device types, including in vitro diagnostic (IVD) devices and active implantable medical devices. These provisions apply once a device is made available on the GB market and cover manufacturer responsibilities related to incident notifications, as well as corrective and preventive actions taken post-approval. The requirements are tailored based on device type and the chosen conformity assessment route, with custom-made devices subject to a more limited set of obligations.
The Statutory Instrument (SI) 2024 No. 1368 is supported by official MHRA guidance, which helps interpret specific obligations but does not replace the legal text. Notably, PMS obligations do not apply to devices involved in clinical investigation, performance evaluation, or those manufactured in-house by healthcare establishments.
Devices that are fully discontinued before 16 June 2025 are exempt from the new rules, but if any individual units are placed on the GB market after this date, full compliance with the updated PMS framework is required. Manufacturers are encouraged to implement a single, harmonised PMS system across all product lines to simplify compliance, especially as the new requirements are more rigorous than previous standards. Devices placed on the market in Northern Ireland continue to follow distinct EU-aligned provisions for legacy devices.
Summary of Key Changes Medical Device Manufacturers Must Know
The 2024 amendments to the UK MDR 2002 introduce significant changes to post-market surveillance (PMS) requirements for medical devices in Great Britain. These changes, effective from 16 June 2025, aim to enhance patient safety and ensure timely identification and management of device-related risks. The summary of main changes provided by the MHRA provide a good review of the key changes made, however, these can be distilled into two main areas: PMS System (PMS Plans + Periodic Reporting) and Vigilance.
Mandatory PMS Plans
Under the amended UK MDR 2002, manufacturers are required to implement a comprehensive PMS Plan for each medical device placed on the Great Britain market. The PMS Plan must be proportionate to the device’s risk classification and should detail processes for collecting, assessing, and analysing data related to the device’s performance and safety throughout its lifetime.
Key elements include methods for gathering information on serious incidents, field safety corrective actions, user feedback, and other relevant data sources. The plan must also outline procedures for data analysis, risk assessment, and the implementation of corrective and preventive actions.
Additionally, manufacturers must ensure that the PMS Plan is integrated with their risk management processes and is maintained for the entire PMS period of the device.
Periodic Reporting

Manufacturers of Class I medical devices (including I(s), I(m), and I(r)) and lower-risk IVDs (Class A, A(s), B, and General IVDs) are required to compile a PMS Report. This report should summarise the findings and conclusions from the ongoing PMS activities related to the safety and performance of the device. While there is no routine submission requirement, the report must be readily available to the MHRA upon request (within 3 working days) and must be updated at least every three years.
For higher-risk medical devices (Class IIa, IIb, III) and higher-risk IVDs (Class C, D, and those listed as Annex II IVDs), manufacturers must prepare a Periodic Safety Update Report (PSUR). This report provides a more detailed assessment of post-market data, including benefit-risk evaluation and a summary of corrective actions taken. Where applicable, the PSUR must be submitted to the UK Approved Body, and it must be made available to the MHRA on request. Class IIa devices require PSUR updates at least every two years, while Class IIb, III, and high-risk IVDs must have their PSUR updated annually.
Enhanced Incident Reporting
The 2024 amendments introduce stricter timelines and clearer expectations for how manufacturers must report serious incidents involving medical devices on the GB market. The addition of new definitions
These changes are intended to enable faster regulatory responses and improve patient safety through better traceability and accountability.
Reporting Timelines: Manufacturers must now report serious incidents within 15 calendar days of becoming aware of them. This marks a significant change from the previous 30-day window and aligns more closely with international vigilance requirements.
Inclusion of Unique Device Identifier (UDI): Where applicable, manufacturers are required to include the UDI in incident reports. This facilitates faster identification and tracking of affected devices across healthcare systems.
Scope of Reportable Events: The definition of what constitutes a reportable incident has been expanded. It now includes events where a device malfunction, deterioration in performance, or usability issue could have led to serious harm, even if no actual injury occurred. This proactive reporting approach ensures that near misses and latent hazards are addressed before resulting in harm.
UK RP Involvement: Non-UK manufacturers may coordinate with their UK Responsible Person (UK RP) to ensure timely reporting and communication with the MHRA. The Responsible Person must maintain vigilance records and be prepared to support investigations if required.
Corrective & Preventive Actions (CAPA): When an incident report leads to a Field Safety Corrective Action (FSCA), manufacturers must document the action, assess its effectiveness, and communicate relevant details to the MHRA and affected parties, including healthcare providers and distributors, and the UKRP, if applicable.
Record Retention: All incident records must be kept as part of the manufacturer’s PMS documentation. These records must be readily accessible and made available to the MHRA upon request, forming part of ongoing compliance audits or enforcement actions.
These enhanced requirements mean that manufacturers must review and update their internal vigilance and complaint-handling procedures. This includes ensuring staff are trained on recognising reportable events, escalating them appropriately, and completing reports in a timely and compliant manner. Strong coordination between regulatory, quality, and customer service teams will be essential to meet the MHRA’s expectations.
Who Must Comply with the New UK PMS Rules?
UKCA-Marked Devices
If your device carries the UKCA mark and is placed on the GB market, you must fully comply with the UK MDR 2002 PMS requirements from 16 June 2025. This includes establishing PMS systems, preparing PSURs/PMSRs and reporting incidents under the new timeframes.
CE-Marked Devices
Manufacturers with CE marked devices still allowed under UK transitional provisions must also meet these UK post-market surveillance obligations. It is advisable to implement a single PMS system that satisfies the new UK requirements; this will likely ensure continued EU compliance but should be reviewed on a case-by-case basis.
How to Prepare for the 2025 PMS Compliance Deadline
We recommend the current strategy in complying with the UK PMS amendments.
Gap Assessment
Start with a gap assessment of your existing PMS and vigilance systems. In doing so, you will identify the changes that must be made in order to comply with the new requirements. It’s advisable to maintain a single plan and report for both the UK and EU for each of your devices; this will avoid duplication of effort.
PMS Plans & Schedule
Put together or amend your existing PMS Plans for all medical devices you will be placing on the GB market. Each plan shall outline clearly how data will be generated, analysed and used.
Establish internal timelines and responsibility for creating, reviewing, and retaining PSURs or PMS summary reports.
Training
Train staff on updated vigilance and reporting procedures to ensure they know how to identify, report, and follow-up incident reports. Ensure that all relevant stakeholders, including the UK RP and distributors are also aware of their obligations.
Final Thoughts: Why This UK PMS Guide Matters
The UK MDR 2002 post-market surveillance amendment marks a crucial shift in how medical device safety is monitored in Great Britain. For manufacturers, both UKCA and CE marked, adapting your PMS systems ahead of the 16 June 2025 deadline is not optional, it’s essential for market access and ongoing regulatory compliance.
We support medical device manufacturers navigating the new UK post-market surveillance regime. Contact us for strategic compliance support, PMS planning, or document preparation aligned with the UK MDR 2002 amendments.