Updated March 2026. Reflects MDCG 2025-7 Rev. 1, MDCG 2025-8, MDCG 2024-14 Rev. 1, Delegated Regulation 2025/788, and Delegated Regulation 2025/1920.
If you manufacture contact lenses, spectacle frames, spectacle lenses, or ready-to-wear reading spectacles for the EU market, there’s a UDI requirement that applies specifically to your products: the Master UDI-DI. It’s been in development for several years, the legislation is now in place, and the implementation guidance has been published for all product categories.
This article covers the general framework: what Master UDI-DI is, how the identifier hierarchy works, which devices are affected, the key dates, and what the gap periods between Eudamed registration and mandatory Master UDI-DI assignment mean in practice.
For the detailed assignment rules, worked examples, and labelling guidance for each product category, see our dedicated articles:
- Contact lenses: Master UDI-DI for Contact Lenses (coming soon)
- Spectacle frames, lenses, and reading spectacles: Master UDI-DI for Spectacle Lenses, Frames, and Reading Spectacles
What is a Master UDI-DI?
A Master UDI-DI is a grouping identifier for highly individualised medical devices (HIDs). Rather than assigning a separate UDI-DI for every individual product variant, it allows manufacturers to group devices that share the same clinically relevant design parameters under a single identifier for registration in Eudamed and labelling purposes.
The problem it solves is straightforward. A single spectacle lens product line can cover hundreds or thousands of prescription combinations. A contact lens range can have just as many variants based on base curve, diameter, and power combinations. Assigning a separate UDI-DI to each would flood Eudamed with identifiers and create an unmanageable burden for manufacturers, distributors, and regulators. The Master UDI-DI groups similar devices under one code while preserving traceability through the UDI-PI (production identifier).
Note: The Master UDI-DI does not replace the Basic UDI-DI. The Basic UDI-DI remains mandatory for all MDR CE-marked devices. Devices qualifying as highly individualised require both a Basic UDI-DI and a Master UDI-DI.
The identifier hierarchy
Understanding how the three identifiers relate to each other is fundamental to getting the schema right.
Basic UDI-DI groups devices sharing the same intended purpose, risk class, and essential design characteristics. It is not placed on the device label. It is registered in Eudamed and referenced in the EU Declaration of Conformity. One Basic UDI-DI can link to many Master UDI-DIs.
Master UDI-DI groups HIDs by clinically relevant design parameters within a Basic UDI-DI. It acts as the UDI-DI for these products. It appears on the device label and is registered in Eudamed. Each Master UDI-DI links to exactly one Basic UDI-DI.
UDI-PI (production identifier) is the lot number, serial number, manufacturing date, or expiry date that identifies the individual device or batch. It appears on the label. The UDI-PI type is recorded in Eudamed, but the actual value is only reported in the Vigilance and Post-Market Surveillance module in the event of a serious incident.
The full UDI for a highly individualised device is: Master UDI-DI + UDI-PI.
Which devices qualify as highly individualised?
Under EU MDR Annex VI, Part C, the following device types are currently recognised as highly individualised devices:
- Contact lenses (standard soft, rigid gas permeable, and made-to-order), classified as Class IIa (short-term use) or Class IIb (long-term use) per MDCG 2021-24
- Spectacle frames, classified as Class I
- Spectacle lenses, classified as Class I
- Ready-to-wear reading spectacles, classified as Class I
Each product category has its own Delegated Regulation and MDCG implementation guidance, with different assignment parameters and mandatory dates.
The legal framework at a glance
The Master UDI-DI sits within a layered regulatory structure. Here’s how it fits together:
EU MDR (Regulation 2017/745), Annex VI, Part C provides the overarching UDI framework. Sections 6.6.1 and 6.6.2 (as amended) introduce the Master UDI-DI provisions for HIDs.
Regulation (EU) 2024/1860 amended the MDR to establish the gradual roll-out of Eudamed, including the timeline for mandatory use of the UDI/Device registration module.
For contact lenses:
- Commission Delegated Regulation (EU) 2023/2197 introduced the Master UDI-DI assignment rules for contact lenses (Annex VI, Part C, Section 6.6.1)
- Commission Delegated Regulation (EU) 2025/788 amended the date of application from 9 November 2025 to 9 November 2026
- MDCG 2024-14 Rev. 1 provides implementation guidance (updated August 2025)
For spectacle frames, spectacle lenses, and ready-to-wear reading spectacles:
- Commission Delegated Regulation (EU) 2025/1920 introduced the Master UDI-DI assignment rules for spectacles (Annex VI, Part C, Section 6.6.2), applicable from 1 November 2028
- MDCG 2025-8 provides implementation guidance (November 2025)
Covering all HIDs:
- MDCG 2025-7 Rev. 1 is the position paper clarifying the timeline interactions between UDI labelling, Eudamed registration, and Master UDI-DI mandatory dates (December 2025)
Key dates
| Date | Milestone | Applies to |
|---|---|---|
| 26 May 2023 | UDI labelling mandatory for Class IIa and IIb devices | Contact lenses (Class IIa/IIb) |
| 26 May 2025 | UDI labelling mandatory for Class I devices | Spectacle frames, lenses, reading spectacles |
| 28 May 2026 | Eudamed UDI/Device registration module mandatory | All medical devices |
| 9 November 2026 | Master UDI-DI mandatory for contact lenses | Contact lenses |
| Q2 2027 (est.) | Eudamed Vigilance and PMS module mandatory | All medical devices |
| 1 November 2028 | Master UDI-DI mandatory for spectacle products | Spectacle frames, lenses, reading spectacles |
The Eudamed UDI/Device registration module became mandatory on 28 May 2026, six months after the publication of the Commission Decision (EU) 2025/2371 confirming the module’s functionality in the Official Journal (27 November 2025).
Products manufactured before the relevant Master UDI-DI mandatory date are not required to carry a Master UDI-DI on the label. Voluntary early adoption before the mandatory dates is, however, strongly encouraged by all three MDCG guidance documents.
The gap periods
One of the most practically important points in MDCG 2025-7 Rev. 1 is the gap between Eudamed registration becoming mandatory and the Master UDI-DI becoming mandatory. During these windows, the UDI/Device registration module must be used, but the Master UDI-DI solution is not yet required.
Contact lenses: approximately 5 months (May 2026 to November 2026). This is a relatively short gap, and manufacturers should already be preparing.
Spectacle frames, lenses, and reading spectacles: approximately 29 months (May 2026 to November 2028). This is a much longer gap, during which manufacturers should register using existing identifiers (GTINs, internal codes, or Eudamed-generated identifiers) while preparing their Master UDI-DI schemas in parallel.
During these gap periods, HIDs will continue to be identified with either an issuing entity identifier (e.g. GTIN) or an internal manufacturer device identifier, following current procedures.
Issuing entity standards
The Master UDI-DI codes are obtained from EU-designated UDI issuing entities. The four designated entities are GS1, HIBCC, ICCBBA, and IFA.
For contact lenses, GS1 has already published its standard (GSCN 21-283), which introduces the Highly Individualised Device Registration Identifier (HIDRI) using Application Identifier (8014), based on the GS1 Global Model Number (GMN) format. Contact lens manufacturers using GS1 can already obtain their Master UDI-DI codes.
For spectacle products, the GS1 standard is not yet finalised as of early 2026. The GS1 working group completed its review and was targeting an eBallot in February 2026, with the GSCN expected in Q2 2026. The spectacle standard is expected to follow a similar approach to the contact lens standard.
This means spectacle manufacturers can define their assignment schemas now (mapping products to Basic UDI-DIs and Master UDI-DIs) but may not yet be able to obtain the actual coded identifiers from their issuing entity. Building the schema now ensures you’re ready to request codes as soon as the standard is published.
Packaging and higher levels
The packaging rules follow the same principle across all HID categories. Per the MDR, higher levels of packaging must have their own UDI-DI. Since the Master UDI-DI replaces the UDI-DI for HIDs, higher levels of packaging must have their own Master UDI-DI where applicable.
In practice, this only applies when a secondary packaging unit contains devices that all share the same Master UDI-DI and constitutes a single sales unit. If the outer packaging contains devices with different Master UDI-DIs (which is common for assorted packs), it is treated as a shipping container and should not have a Master UDI-DI assigned to it.
Vigilance reporting
When a serious incident occurs involving an HID, the manufacturer must provide the full UDI (Master UDI-DI + UDI-PI) in the Manufacturer Incident Report, whether submitted via the PDF MIR form or through the Eudamed Vigilance module.
Because one Master UDI-DI covers a group of devices, the manufacturer must also use internal QMS and product traceability systems to precisely identify the specific device(s) involved in the incident.
An important nuance from MDCG 2025-7 Rev. 1: once the Eudamed Vigilance module becomes mandatory (estimated Q2 2027), the Master UDI-DI should be used for vigilance reporting if it has been assigned, even if the mandatory application date for that device category has not yet passed.
What you should be doing now
Regardless of which product category you manufacture, the preparatory steps are similar:
Catalogue your product range. Document every variant: materials, construction types, sizes, refractive indices, design types, prescription ranges. This data feeds your assignment schema.
Build your assignment schema. Map your catalogue against the Basic UDI-DI and Master UDI-DI assignment rules for your product category. The detailed rules differ by category and are covered in our product-specific articles.
Engage with your issuing entity. If you’re a GS1 member, monitor progress on the relevant GSCN. If you don’t have an issuing entity relationship yet, start establishing one.
Register in Eudamed. The UDI/Device registration module is already mandatory. Use your existing identifiers for now and plan to update with Master UDI-DIs when available and mandatory.
Plan your labelling updates. Each Master UDI-DI needs its own barcode on the label. Assess how many label variants you’ll need and factor in artwork and print lead times.
Review your vigilance processes. Make sure your QMS can support reporting at the Master UDI-DI level, including the ability to trace individual devices within a group.
How we can help
At Specculo, we work with optical device manufacturers to navigate the Master UDI-DI framework from schema design through to Eudamed registration. That includes:
- Assessing whether your products qualify for Master UDI-DI grouping and determining the correct assignment parameters
- Building your Basic UDI-DI and Master UDI-DI assignment schema, mapped to your product catalogue
- Advising on labelling updates to incorporate Master UDI-DI and UDI-PI carriers
- Structuring your device data for correct registration in the Eudamed UDI/Device module
- Supporting your issuing entity engagement (GS1, HIBCC)
- Reviewing vigilance and PMS processes for Master UDI-DI readiness
Whether you need a workshop to understand the framework and build the schema yourself, or you’d prefer us to take the project end to end, we’ll tailor the engagement to your team and timeline.
Need help with your Master UDI-DI strategy? Get in touch for an initial consultation, or explore our regulatory strategy and Eudamed registration services.
Further reading
Our product-specific guides:
- Master UDI-DI for Contact Lenses (coming soon)
- Master UDI-DI for Spectacle Lenses, Frames, and Reading Spectacles
Official sources:
- MDCG 2025-7 Rev. 1: Position Paper on timelines of Master UDI-DI implementation
- MDCG 2024-14 Rev. 1: Implementation guidance for contact lenses
- MDCG 2025-8: Implementation guidance for spectacle products
- Commission Delegated Regulation (EU) 2023/2197 (contact lenses)
- Commission Delegated Regulation (EU) 2025/788 (contact lens date amendment)
- Commission Delegated Regulation (EU) 2025/1920 (spectacle products)
- European Commission: Unique Device Identifier (UDI) page
- Understanding the Basic UDI-DI: A Key Regulatory Identifier for Medical Devices
This article is current as of March 2026. We’ll update it as the GS1 spectacles GSCN is published and as further Eudamed modules come online.