What is the Basic UDI-DI?
The Basic UDI-DI (Unique Device Identification – Device Identifier) is a regulatory identifier that acts as the primary key for a family or model of medical devices sharing common features. Specifically, it links devices with the same:
- Intended purpose.
- Risk classification.
- Essential design and manufacturing characteristics.
Unlike the UDI-DI, which identifies individual products and appears on labels or packaging, the Basic UDI-DI remains behind the scenes as it is not printed on the device or its packaging. Instead, it serves regulatory and administrative functions, such as device registration and certification.
Importantly, the Basic UDI-DI does not replace the UDI-DI. Both identifiers serve distinct but complementary regulatory functions
The Basic UDI-DI is mandatory under EU MDR (2017/745) and IVDR (2017/746). It must be assigned before placing a device (excluding custom-made devices) or System or Procedure pack on the EU market, as outlined in Article 27(2) of the MDR/IVDR.
MDCG 2018-1 v3 Guidance on BASIC UDI-DI and changes to UDI-DI provides additional information on Basic UDI-DI.
Who is responsible for the Basic UDI-DI?
The responsibility for assigning the Basic UDI-DI lies solely with the medical device manufacturer. It must be issued following the rules of a designated UDI issuing agency recognised by the European Commission.
Note: Authorised representatives, importers and distributors do not assign the Basic UDI-DI but must verify its presence in regulatory documentation.
Where Should the Basic UDI-DI be Displayed?
Although not displayed on product labels, the Basic UDI-DI must appear in several key regulatory documents, including:
- Technical documentation
- EU Declaration of Conformity
- Notified Body certificates
- Summary of Safety and Clinical Performance (if applicable)
The Basic UDI-DI is also used during device registration in Eudamed.
Rules for Assigning the Basic UDI-DI
Here are the golden rules to take into consideration when assigning a Basic UDI-DI for your device family:
Rule 1: A single Basic UDI-DI must be assigned to each group of devices that share the same intended purpose, risk classification, and essential design and manufacturing characteristics.
Rule 2: A Basic UDI-DI can be linked to multiple UDI-DIs, representing individual device variants within the same device family.
Rule 3: A UDI-DI must not be associated with more than one Basic UDI-DI.
How is the Basic UDI-DI Generated?
Manufacturers must obtain a Basic UDI-DI from a recognised UDI-issuing agency. As of now, the following agencies are approved for EU use:
- GS1
- HIBCC
- ICCBBA
- IFA
Most manufacturers go with GS1 or HIBCC, depending on internal preferences and system compatibility. Each agency has specific formatting rules, but general requirements according to MDCG 2019-1 include:
- Maximum of 25 characters
- Code format created should be similar to the existing UDI-DI format
- Inclusion of a check/digit character, based on a defined algorithm
GS1
Within the GS1 system, the Basic UDI-DI is referred to as the Global Model Number (GMN). It consists of three main elements:
- GS1 Company Prefix: A unique identifier assigned to the manufacturer upon registering with GS1. This prefix forms part of the GMN and establishes the manufacturer’s identity.
- Model Reference: Created by the manufacturer. This alphanumeric code is not standardized by GS1 and can follow the manufacturer’s internal product coding system.
- Check/Digit Character: Automatically generated using the GS1 check character calculator dedicated webpage

The combined Company Prefix + Model Reference may be up to 23 characters, with the additional two check digits assigned at the end based on GS1’s algorithm.
HIBCC
HIBCC uses a slightly different format, but the goal is the same: a reliable, trackable identifier for your device family.
Here’s the breakdown:
- Flag Characters (“++”): Indicate that the Basic UDI-DI was created under HIBCC rules.
- Labeler Identification Code (LIC): A unique, alphanumeric code (starting with a letter) assigned when applying with HIBBC. It identifies the organisation responsible for the Basic UDI-DI.
- Global Model Identifier: Created and managed by the LIC holder. This segment is not standardised by HIBCC and may follow the manufacturer’s own coding structure.
- Check/Digit Character: Calculated using Mod 1021 and Mod 32 to validate the identifier.

Like GS1, the combination of LIC + Global Model Identifier can be up to 23 characters long, with the additional two check digit assigned at the end.
How Specculo can help with Basic UDI-DI
Assigning and managing the Basic UDI-DI correctly is critical for compliance with EU MDR and IVDR requirements, and a prerequisite for device registration in Eudamed. Specculo provides expert guidance to help you get it right the first time.
We support manufacturers in:
- Determining appropriate device groupings based on intended use, classification, and design.
- Interpreting and applying MDCG guidance to ensure valid assignment rules are followed.
- Navigating GS1 and HIBCC systems to generate and structure your Basic UDI-DIs.
- Verifying use of the Basic UDI-DI across required documentation, including technical files, Declarations of Conformity, and Notified Body certificates.
- Aligning your UDI-DI and Basic UDI-DI structure to avoid duplication or regulatory inconsistencies.
Whether you’re building your UDI framework from scratch or validating existing assignments, we help ensure your identifiers are fully compliant and ready for regulatory review.
Reach out for an initial consultation or regulatory strategy offered by our team of consultants.